Articles | Volume 20, issue 9
https://doi.org/10.5194/tc-20-5265-2026
https://doi.org/10.5194/tc-20-5265-2026
Brief communication
 | 
21 Sep 2026
Brief communication |  | 21 Sep 2026

Brief communication: Limitations of medical X-ray computed tomography for estimating ice content in permafrost samples

Mahya Roustaei, Jonas Darey, Zakieh Mohammadi, and Daniel Fortier

Related authors

Ground ice estimation in permafrost samples using industrial computed tomography and multi-sensor core logging and comparison to destructive measurements
Mahya Roustaei, Joel Pumple, Jordan Harvey, and Duane Froese
The Cryosphere, 19, 4259–4275, https://doi.org/10.5194/tc-19-4259-2025,https://doi.org/10.5194/tc-19-4259-2025, 2025
Short summary
Non-destructive multi-sensor core logging allows for rapid imaging and estimation of frozen bulk density and volumetric ice content in permafrost cores
Joel Pumple, Alistair Monteath, Jordan Harvey, Mahya Roustaei, Alejandro Alvarez, Casey Buchanan, and Duane Froese
The Cryosphere, 18, 489–503, https://doi.org/10.5194/tc-18-489-2024,https://doi.org/10.5194/tc-18-489-2024, 2024
Short summary

Cited articles

Calmels, F. and Allard, M.: Ice segregation and gas distribution in permafrost using tomodensitometric analysis, Permafrost Periglacial, 15, 367–378, https://doi.org/10.1002/ppp.508, 2004. 
Calmels, F. and Allard, M.: Segregated ice structures in various heaved permafrost landforms through CT Scan, Earth Surf. Processes Landf., 33, 209–225, https://doi.org/10.1002/esp.1538, 2008. 
Calmels, F., Clavano, W., and Froese, D.: Progress on X-ray Computed Tomography (CT) Scanning in Permafrost Studies, in: Proceedings of the 6th Canadian Conference on Permafrost, 63rd Canadian Geotechnical Conference & 6th Canadian Permafrost Conference, Calgary, AB, Canada, 1353–1358, 2010. 
Capowiez, Y., Pierret, A., Daniel, O., Monestiez, P., and Kretzschmar, A.: 3D skeleton reconstructions of natural earthworm burrow systems using CAT scan images of soil cores, Biol. Fert. Soils, 27, 51–59, https://doi.org/10.1007/s003740050399, 1998. 
Clausnitzer, V. and Hopmans, J. W.: Pore-scale measurements of solute breakthrough using microfocus X-ray computed tomography, Water Resour. Res., 36, 2067–2079, https://doi.org/10.1029/2000WR900076, 2000. 
Download
Short summary
This study assesses the accuracy of medical X-ray computed tomography (CT) for estimating volumetric ice content in permafrost samples. Comparison of 261 cores from northern Canada shows that medical CT systematically underestimates ice in sediment-rich samples and overestimates it in organic-rich ones due to resolution limits and material misclassification. The results highlight medical CT's value for visualizing cryostructures but its limits for quantitative ice estimation.
Share