Brief communication: Limitations of medical X-ray computed tomography for estimating ice content in permafrost samples

Mahya Roustaei, Jonas Darey, Zakieh Mohammadi, and Daniel Fortier

Viewed

Total article views: 2,336 (including HTML, PDF, and XML)
HTML PDF XML Total BibTeX EndNote
1,520 609 207 2,336 197 204
  • HTML: 1,520
  • PDF: 609
  • XML: 207
  • Total: 2,336
  • BibTeX: 197
  • EndNote: 204
Views and downloads (calculated since 15 Dec 2025)
Cumulative views and downloads (calculated since 15 Dec 2025)

Viewed (geographical distribution)

Total article views: 2,336 (including HTML, PDF, and XML) Thereof 2,317 with geography defined and 19 with unknown origin.
Country # Views %
  • 1
1
 
 
 
 
Latest update: 12 Oct 2026
Download
Short summary
This study assesses the accuracy of medical X-ray computed tomography (CT) for estimating volumetric ice content in permafrost samples. Comparison of 261 cores from northern Canada shows that medical CT systematically underestimates ice in sediment-rich samples and overestimates it in organic-rich ones due to resolution limits and material misclassification. The results highlight medical CT's value for visualizing cryostructures but its limits for quantitative ice estimation.